FAQ: Why do I get a noisy trial data message when I try to analyze my data?
By
Equinosis Staff |
Updated on
|
Equinosis Staff,
FAQ,
Locked,
Noisy Trial Data
If you receive a noisy trial data message following data collection and attempting to generate an analysis, check the following: Make sure that the RF gyroscope sensor is on the dorsal midline of the RF pastern. Placing the sensor on the side of the pastern, or above the fetlock will produce erratic or unusable data. Sensor rotation is prevented by using Elastikon® type tape around the wrap, including some of the hair above the wrap. Check that the RF sensor is stable within the sensor pouch (attached and clicked into the dual lock tape). Place a piece of vetwrap, Elastikon®,...